Transformer test report pdf

The type and routine test are very important for transformer. Transformers have been used at powerplants since the inception of. Turnsratio test results should not deviate more than onehalf percent from either the adjacent coils or the calculated ratio. Sweep frequency response analysis test sfra test electrical4u. Page 1 of 8 reference sp0504r01 ver 1 reference owner. Test report iec 6155826 safety of power transformers, power. Nov 17, 2019 sweep frequency response analysis test or in short sfra test can detect efficiently, displacement of transformer core, deformation and displacement of winding, faulty core grounds, collapse of partial winding, broken or loosen clamp connections, short circuited turns, open winding conditions etc. In transformer oil has mainly two purposes, first for insulation, second as cooling of. Microsoft word cover page job quality assurance plan.

This test also performed as a routine test of transformer. Variations of type 1 transformers may exist pending past records and age of units. So transformer ratio test is an essential type test of transformer. So for ensuring proper performance of electrical power transformer, voltage and turn ratio test of transformer one of the important tests. Power transformer no load loss test report sp0504c05. The high voltage winding of the transformer under test and the high. Dielectric strength means the maximum capacity to withstand voltage of insulating oil.

Ensure the ct is connected to system properly in all respect primary and secondary. Type 2 this category covers any transformer showing test results where some concern is evident re test recommended in six months. Before proceding with transformer measurements the test engineer will become familiar with the safety rules of section 2. This will be accomplished through a short circuit and open circuit test. Power transformer load loss and impedance calculation sp0504c08. Electrical transformer quiz questions electrician exams. See appended table refers to a table appended to the report. High voltage testing of transformer seminar report pdf. Following is an approximate sequence for transformer testing. Power transformer testing fat test inspection for industry. Transformer testing type tests and routine tests of. Power transformer no load loss test report form sp0504c04 power transformer load loss test report form sp0504c05 and load loss calculation forms. It is done for checking the dielectric strength of the oil of the transformer.

Polarity test of transformer polarity means the direction of the induced voltages in the primary and the secondary winding of the transformer. Noise measurements of the power transformers aleksandra petrovic1, ljubomir lukic1, milan kolarevic1. Transformer test report free download as excel spreadsheet. Transformers noise depends on the power, and a number of. For example, unless there is reason to be concerned about winding deformation, a leakage reactance test is probably not necessary.

Release to operations and report energization information to the tne office. We are pleased to submit the insulating fluid report and test sheets for the three 3 transformers and one 1 ocb located at the north vancouver facility. If the two transformers are connected in parallel, then the polarity should be known for the proper connection of the transformer. The battery negative terminal is connected to current transformer terminal h2 and the positive side is left hanging for. Dewa power transformer site test report format free download as pdf file. It has been developed with the assistance of bureau of reclamation engineers. These symptoms also result in an increase of losses, which can be quantified by measuring the power factor or dissipation factor. The typical excitation current test data pattern for a threelegged core transformer is two similar current readings and one lower current reading. You will be using the transformer as a stepdown transformer with a 11. Noise measurement of transformer 112 mva the test procedure is in accordance with iec standard 6007610.

Transformer testing type test and routine test of transformer electrical4u. Our own oil analysis laboratory directly links the results from. Smit transformer services tap changer specialists hold the mr premium service provider certificate. Dryddrryydry type power transformertype power transformertype power transformer designation trasformatore rated power kva number of phases 3 rated voltage of the highvoltage winding primary winding 15 kv.

It is also done at site to ensure healthiness of a transformer that is to check loose connections, broken strands of conductor, high contact resistance in tap changers, high. Gdbrp transformer power analyzertransformer power analyzer. Testing of power transformers seems like a similar experience. Because a test confirms what you know, if you can apply in real life what you have learned in a classroom, under strict, rigorous and controlled conditions.

Transformer bushing cts should be tested using the current ratio test method before the transformer has been completely assembled. Demand test report routine test report standard type test report special test report paid. Testing and diagnostics of power transformers brochure 4. Type test are conducted on a transformer which is a representative of other transformers, to demonstrate that these transformers comply with specified requirements not covered by routine tests. The installation and testing of the transformer verifies its condition at the time it is ready for. Home about us products application fields download center photos news contact us. Job safety analysis power transformer testing check this is the latest process zone version before use. Routine test are the mandatory tests to be carried out on each individual transformer. There are two types of polarity one is additive, and another is subtractive. A dga test can identify an overloaded transformer by a test result showing high carbon monoxide, high carbon dioxide, and in extreme cases, even elevated methane and ethylene. Transformers are an electrical component that transmit electrical energy between at least two circuits. The primary incentive is to make sure the transformers meet manufacturing. Finish load test under kva below distribution transformer full current for single machine.

To study the variation of iron loss and no load current with the applied voltage. The purchase, preparation, assembly, operation and maintenance of transformers represent a large expense to the power system. Power transformer testing competency assessment sp0504c. The equivalent model of a real transformer is as follows. Transformer type oil type transformer cast resin dry type transformer. Nema disclaims liability for any personal injury, property, or other damages of any nature. The connection arrangement for a kick test for a current transformer is presented in figure 3. You have to finish following quiz, to start this quiz. Mt779601 6sep15 hv test pty ltd leader in high voltage test equipment pula steel selebi phikwe transformer test report 2. The power transformer testing fat test is performed after completion of the assembly at the manufacturing shop.

Routine tests and type tests of transformers electrical4u. Also the hard copies as per specification shall be submitted. Type test procedure iec, nec, nema, fdf, iso ansi, ci, ipcea iec, nec, nema, fdf, iso ansi, ci, ipcea procedure h r a inspection and test plan for power transformer before manufacturing activity by. Inspect transformer and parts for shipping damage and moisture. A varying current in the first or primary winding creates a varying magnetic flux in the. Powerfactor or dissipationfactor tipup exceeding 1. As a result of the owner company, the importance of the machine and the outage possibilities, it is necessary to. Transformer testing commissioning, routine, diagnostic. Testing power transformers highvoltage transformers are some of the most important and expensive pieces of. The transformer sampling was performed by james powell on june 7, 2016 in accordance with astm d923 and d36 standards. Evaluating transformer condition using dga oil analysis. As it checks the quality of material used and the procedure of transformer manufacturing hence provide us details of life of transformer, the transformer behaviour on different faults. Testing of current transformers, voltage transformers or auxiliary transformers internal to.

The test results presented in this report relate only to the object tested. Transformer testing type tests and routine tests of transformer. The procedure of the transformer ratio test is simple. These result in a shorted turn the core and produce high currents which are often detected by dissolved gas analysis. These tests are done to assess the condition of transformer after installation and compare the test results of all the low voltage tests with the factory test reports. Transformers regulate the voltage in circuits, but in some cases these can go bad and cause a circuit to not. Open circuit and short circuit tests of a singlephase transformer aim. If the transformer is new, the resistance test also serves as a verification of the manufacturers work. Complete tests 1 and 2 for each winding of a threephase transformer individually with the remaining windings kept open. Dewas project site test report for power transformer. This report shall not be reproduced, except in full, without the written approval of the issuing testing laboratory.

I want to learn transformer testing so can you send pdf to my mail because here i cant download it so please. Ms excel spreadsheet electrical engineering portal. Mainly two types of transformer are done by manufacturer before dispatching the transformer mainly 1 type test of transformer and 2 routine test. Ece 494 electrical engineering laboratory iii lab 3. The electrical field tests recommended for routinely testing a transformer include. There are various test required on transformer to conform performance of transformer. So, insulation overheating measurement is also transformer oil testing methods. Ensure that all equipment to be tested is properly grounded and treat all highvoltage power equipment as energized until proven otherwise by using the proper lockouttagout procedures. Pdf early detection of incipient faults in transformers reduces costly unplanned outages. Dewa power transformer site test report format transformer. Basics, maintenance, and diagnostics vii contents continued page 4. Megger provides thoughtfully equipped transformer test instruments for routine screening needs. This test is consequently performed on high voltage side of the transformer terminals 2.

Typical transformer test report transformer electrical components. To conduct standard open and short circuit tests in order to. Completely self protected singlephase polemounted distribution transformer. Sweep frequency response analysis test or in short sfra test can detect efficiently, displacement of transformer core, deformation and displacement of winding, faulty core grounds, collapse of partial winding, broken or loosen clamp connections, short circuited turns, open winding conditions etc. Transformer winding resistance measurement is carried out to calculate the i 2 r losses and to calculate winding temperature at the end of a temperature rise test. The test connection arrangement is shown in figure 2 c. This meter provides a 1 khz, 2 vrms test voltage and displays the dominant reactive component and associated resistive values serial and parallel resistances, rs and rp, respectively of the device under test. Pdf evaluating transformer condition using dga oil analysis. In addition some other tests are also carried out by the consumer at site before commissioning and also periodically. A circuit, connected to the terminals of the second winding, results in current flow.

Other causes of distribution transformer failure modes can be the result of a grounded core or core clamping structures such as throughbolts that develop shorts. Manufacturers test thousands of distribution transformers at worldwide locations each week. Cesi test report cesi test report cesi inspection report manufacturers drawings b3006646 b3007311 b30566 b304 no. May 10, 20 so transformer ratio test is an essential type test of transformer. Power transformer open and short circuit tests objectives. This ms excel spreadsheet is actually detailed instruction for each procedure necessary for correct testing of power transformer. Checkup position name taps measured ratio power va class measured ratio measured ratio. Two winding transformer impedance measurement positive sequence impedance test circuit for threephase 2winding transformer the positive sequence impedance is measured from a standard short circuit test see figure right. Please provide a selection of test reports and data sheets of planned test objects. It is carried out as a type test as well as routine test. Turnsratio test results should not deviate more than. Demand test report routine test report standard type test report special test report paid your message.

Your name required your email required company name. This test is similar to tests 1 and 2, but as applied to a three phase transformer for phase identification and phase continuity check. Pdf transformer testing type test and routine test of. This test shows the dielectric strength of transformer oil. Testing power transformers highvoltage transformers are some of the most important and expensive pieces of equipment required for operating a power system. Finish 3150kva below distribution transformer load test under rated current under rated current, the instrument can be converted to load loss parameters under rated current.